Logix safety instrumented system (SIS) is a modern and integrated safety solution, offering both SIL2 and SIL3 certifications for enhanced process and hybrid safety.
Loading
  1. Product Selection
  2. Overview
Open All Close All
Product Selection Chevron DownChevron Down
Sort & Filter
CloseClose
Filter & Refine
Clear All
Sort By Chevron UpChevron Up
Chevron UpChevron Up
-
View Results
Showing 1 - 1 of 0 Results
Sort By:
Filter & Refine
Best Selling
Chevron UpChevron Up
Product information Configure product Add to project
Items Per Page:
1 - 1 of 0 Results
CloseClose
Number of compared products:
0
CloseClose
CloseClose
CloseClose
CloseClose
Clear All
Compare Now (0)
Overview Chevron DownChevron Down

Logix SIS is a modern and integrated safety solution, offering both SIL2 and SIL3 certifications for process and hybrid safety. The system is engineered for high availability, providing robust protection against industrial hazards while reducing overall lifecycle costs.

Allen-Bradley logo

Introducing Logix SIS: A New Logix Based High Availability Safety Solution

Logix SIS is a new Process Safety offering built on the same control and software infrastructure as the base process control system (BPCS) for ease of use and integration.

Logix SIS modernizes safety control requirements with the latest hardware and software, providing a simplified approach for easy implementation.

A Modern and Integrated Safety Backup System

  • Enhanced Safety: Our SIS solutions are engineered to help detect and mitigate potential hazards before they become critical, achieving the safety of your personnel and equipment.
  • High Availability: With built-in redundancy and failover mechanisms, our systems help achieve continuous operation, minimizing downtime and maximizing productivity.
  • Scalability: Whether you operate a small facility or a large industrial plant, our SIS solutions are scalable to meet your specific needs, growing with your business.
  • Compliance: Stay ahead of regulatory requirements with our SIS solutions designed to meet the highest industry standards.
  • Cost Efficiency: By reducing the risk of incidents and unplanned shutdowns, our SIS solutions help you save on operational costs and reduce the total cost of ownership.
Loading

How will Logix SIS benefit me over the lifecycle of my system?

Arrow Up

Meet industry standards for SIS leveraging modern hardware platforms and simplifying implementation.

Safety icon

Achieve critical safety functions to help prevent hazardous incidents and help protect personnel, assets, and the environment.

Digital Engineering Icon

Reduce engineering time by using integrated high availability safety functionality.

Unlock the Future of Safety with Integrated Safety Instrumented Systems (SIS)

We understand that your top priority is achieving the safety and reliability of your operations. Our Integrated Safety Instrumented Systems (SIS) are designed to provide you with peace of mind, helping protect your plant through the latest in safety technology.

FLEX 5000® I/O modules

The Logix SIS, a Logix controller-based safety instrumented system (SIS), is used with FLEX 5000® I/O modules to provide a comprehensive Process and Hybrid safety solution. The system complements PlantPAx®, Distributed Control System (DCS)/Basic Process Control System (BPCS) from Rockwell Automation.

Learn More
An image of a typical layout of a phase 1 Logix SIS system with Distributed I/O. The redundant chassis host redundant Safety Logix controllers, as well as redundant network communication modules.

Frequently Asked Questions

Open All
Close All
What modules are supported in the Logix SIS redundancy rack?
Chevron DownChevron Down

All modules that are supported in standard 5580 redundancy are also supported in Logix SIS with the substitution of 5580 ControlLogix® Controllers → 5580 GuardLogix® Controllers. P controllers are not supported in Logix SIS initial release.

What safety I/O is supported with Logix SIS?
Chevron DownChevron Down

Only FLEX 5000® safety I/O modules are supported in the initial release.

Do both controllers connect to the I/O?
Chevron DownChevron Down

Logix SIS makes use of concurrent communications from the safety task meaning both controllers send data packets to the I/O modules through the adapter.

What SIL level is supported?
Chevron DownChevron Down
  • The system can achieve up to SIL 3 when synchronized.
  • SIL 3 is maintained on disqualification if repaired within the Mean Repair Time; otherwise, the system degrades to SIL 2.
  • The system can achieve up to SIL 2 when it is not synchronized.
Can I use a P controller in Logix SIS?
Chevron DownChevron Down

No initial release requires the Logix SIS system to leverage the Red safety controllers.

How can I get this solution?
Chevron DownChevron Down

Product compatibility and download center.

Experience the Difference

Ready to elevate your plant’s safety and performance? Reach out to us now and discover the future of industrial safety!

 

Contact Us

Recommended for You

Loading
Loading
Loading
Chevron DownChevron Down
  1. Chevron LeftChevron Left Rockwell Automation Home Chevron RightChevron Right
  2. Chevron LeftChevron Left Pro... Chevron RightChevron Right
  3. Chevron LeftChevron Left Hardware Chevron RightChevron Right
  4. Chevron LeftChevron Left Programmable Controllers Chevron RightChevron Right
  5. Chevron LeftChevron Left Logix SIS: Process Safety Chevron RightChevron Right
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose
OSZAR »